Reliability of peroneal reaction time measurements

  • Stefan Benesch

      Affiliations

    • Department of Surgery of the Military Hospital, Ulm, Germany
    • Corresponding Author InformationCorresponding author
  • ,
  • Walter Pütz

      Affiliations

    • Department of Trauma Surgery of the Central Military Hospital, Koblenz, Germany
  • ,
  • Dieter Rosenbaum

      Affiliations

    • Department of Orthopedics, University of Münster, Germany
  • ,
  • Horst-Peter Becker

      Affiliations

    • Department of Surgery of the Military Hospital, Ulm, Germany

Received 9 September 1998; accepted 9 April 1999.

Abstract 

Objective. The purpose of this study was to demonstrate the reliability of reaction time-measurements on a tilting platform under consideration of various influencing factors.

Design. The peroneal reaction time of 30 healthy subjects was examined in an experimental study.

Background. Peroneal reaction time measurements have been used to objectively evaluate functional instability of the ankle joint, but the reliability of the method has not been proven yet.

Methods. The reaction time after sudden inversion of the ankle were determined by surface EMG.

Results. The median latency of the peroneus brevis was 66 ms and that of the peroneus longus was 63 ms. No differences between male and female subjects and between left and right legs could be found. An increase of reaction time was caused by neuromuscular fatigue (P=0.033, for both the peroneus brevis and the peroneus longus). A decrease in reaction time resulted if the foot was held in 15° of plantar flexion (P=0.0004 for the peroneus brevis, P=0.002 for the peroneus longus). The reliability was examined by circadian and by day-to-day measurements. The coefficient of correlation (Spearman’s rho) between the peroneus brevis and days 1–5 was 0.67 (P=0.177) and for the peroneus longus 0.00 (P>0.999). The same results were obtained after the circadian measurements.

Conclusion. Determination of peroneal reaction time was proven as a reliable measurement method.

Relevance

Reliability and validity are basic preconditions of a test to become accepted as a clinical measurement method. This paper demonstrates the reliability of measuring the peroneal reaction time. Thus, assuming validity, the peroneal reaction time measurement is justified as a clinical test.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0268-0033(99)00026-1

Clinical Biomechanics
Volume 15, Issue 1 , Pages 21-28, January 2000