Multiple muscle force simulation in axial rotation of the cervical spine

Department Unfallchirurgische Forschung und Biomechanik, Universität Ulm, Helmholtzstraβe 14, 89081 Ulm, Germany

Received 9 September 1997; accepted 24 March 1998.

Abstract 

Objective. To produce axial rotation of the cervical spine in vitro bycoordinated application of eight simulated muscle forces.

Design. Biomechanical testing of the cervical spine by controlled pneumatics.

Background. Some muscle simulation experiments have been performed in vitro in the lumbar spine but data generally are lacking for this testing mode in the cervical spine. Thus, physiological biomechanical behavior in this region remains poorly understood.

Methods. Six human donor cervical spines were loaded by a set of computer-controlled pneumatic cylinders representing pairs of trapezius, splenius and sternocleiodmastoid muscles, plus longus and splenius colli left. Muscle functions were derived from a previously-developed mathematical optimization model. Muscle forces generally were achievable within 2 N of the intended values provided by the model.

Results. Rotation of the head followed fairly closely that predicted by the model. The resulting force components to produce 37 ° were dominated by axial compression of about — 100 N and the resulting moments were similar in all planes at about 2 Nm. Coupled motions were larger than primary motions in some intersegmental behavior.

Conclusions. Slow, physiologic axial rotation of the head may be simulated by a complex and representative series of controlled pneumatics. Controlled rotation results in a relatively high compressive force and occurs through fairly balanced and small moments.

Keywords:  Muscle force simulation, Cervical spine, Biomechanics, In vitro experiment, Coupled motion

No full text is available. To read the body of this article, please view the PDF online.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0268-0033(98)00031-X

Clinical Biomechanics
Volume 14, Issue 1 , Pages 32-40, January 1999