Clinical Biomechanics
Volume 14, Issue 1 , Pages 63-68, January 1999

The scapulo-humeral rhythm: effects of 2-D roentgen projection

Laboratory of Measurement and Control, Faculty of Mechanical Engineering and Marine Technology, Delft University of Technology, Mekelweg 2, 2628 CD, Delft, The Netherlands

Received 16 August 1995; accepted 19 March 1998.

Abstract 

Objective. The objective of this study is to illustrate the low accuracy of two-dimensional (2-D) X-ray projection methods for the quantification of the three-dimensional (3-D) shoulder motions.

Background. The traditional method for the quantification of the gleno-humeral motion is by means of 2-D X-ray recording. The motion was characterized by the scapulo-humeral rhythm: the ratio of the nett humeral elevation over nett scapular rotation. The method was based on the quantification of the planar projection of the spatial positions of X-ray dense structures of the scapula. The deformations introduced by the central projection method, a feature of X-ray projection, cannot be compensated for by calibration: the position of the scapula with respect to the camera setting is unknown, and skeletal landmarks of the scapula cannot uniquely be identified. The transformation from 3-D orientations to 2-D angles will, therefore, be inaccurate.

Methods. A 2-D X-ray projection of the scapula during a typical arm abduction was simulated. The 3-D motion was obtained by means of palpation and subsequent digitization of skeletal landmarks of the scapula. The 3-D positions of the recorded landmarks were projected on a plane by a simulation based on the parameters of the X-ray equipment. The scapulo-humeral rhythm was calculated for the different scapular landmarks, and for the orientation of the subject with respect to the projection axis. The results were compared with previous published scapulo-humeral rhythms.

Results. The scapulo-humeral rhythm depends both on the choice of the skeletal landmarks, used to quantify the scapular rotations, and on the orientation of the subject in the X-ray setting. The full range of results obtained from earlier published experiments could be obtained from a simulation based on a single 3-D arm abduction.

Conclusions. The 2-D scapulo-humeral rhythm, obtained from planar X-ray projection, is an inaccurate parameter to define the scapular motions.

Keywords:  Shoulder, Kinematics, Scapulo-humeral rhythm, X-ray

No full text is available. To read the body of this article, please view the PDF online.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0268-0033(98)00027-8

Clinical Biomechanics
Volume 14, Issue 1 , Pages 63-68, January 1999