Clinical Biomechanics
Volume 13, Issue 1 , Pages 71-76, January 1998

The relative skin movement of the foot: a 2-D roentgen photogrammetry study

  • Roy Tranberg

      Affiliations

    • Corresponding Author InformationCorrespondence and reprint requests to: Roy Tranberg, Department of Biomechanics and Orthopaedic Technology, University of Health Science. P.O. Box 1038, S-551 11 Jönköping, Sweden.
    • Department of Biomechanics and Orthopaedic Technology, University of Health Science, Jönköping, Sweden
  • ,
  • Dan Karlsson

      Affiliations

    • Prosolvia Research and Technology, Jönköping, Sweden

Received 12 December 1996; accepted 18 August 1997.

Abstract 

Objective. This paper describes a validation of the relative motions of skin-mounted markers on the foot.

Design. The movement of a skin-mounted marker on the foot was evaluated by the use of 2-D roentgen photogrammetry.

Background. Validations of skin-mounted markers are needed in order to assess whether clinical use of motion analysis systems is accurate.

Methods. Six healthy volunteers participated in the study. Measurements were made with 2-D roentgen photogrammetry from the medial aspect of the foot. Spherical lead markers, with a diameter of 2 mm, were glued on the skin over the following landmarks: the medial malleolus, the navicular bone, the medial part of calcaneus, the base and the head of the first metatarsal bone, and the base of the fifth metatarsal bone. The foot was placed on a platform that was adjustable in three directions: horizontal, 20 ° upward (towards dorsal flexion), and 30 ° downward (towards plantar flexion).

Results. In relation to the underlying bones, the markers were found to move up to 4.3 mm. The markers with the largest movements were the ones over the medial malleolus, the navicular bone and the calcaneus. For the distally placed markers i.e. at the base and the head of the first metatarsal bone, and the base of the fifth metatarsal bone, the displacements were a maximum 1.8 mm.

Conclusions. Markers mounted on the foot moved between 1.8 and 4.3 mm corresponding to the underlying bones. The most proximal attached markers demonstrated the largest movements.

Keywords:  Biomechanics, gait analysis, ankle complex, foot

No full text is available. To read the body of this article, please view the PDF online.

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0268-0033(97)00052-1

Clinical Biomechanics
Volume 13, Issue 1 , Pages 71-76, January 1998