Clinical Biomechanics
Volume 23, Supplement 1 , Pages S59-S66, 2008

The adaptive response of periodontal ligament to orthodontic force loading – A combined biomechanical and biological study

  • Zhihe Zhao

      Affiliations

    • Department of Orthodontics, West China College of Stomatology, Sichuan University, Chengdu 610041, PR China
    • Corresponding Author InformationCorresponding author.
  • ,
  • Yubo Fan

      Affiliations

    • Bioengineering Department, Beihang University, Beijing 100083, PR China
  • ,
  • Ding Bai

      Affiliations

    • Department of Orthodontics, West China College of Stomatology, Sichuan University, Chengdu 610041, PR China
  • ,
  • Jun Wang

      Affiliations

    • Department of Orthodontics, West China College of Stomatology, Sichuan University, Chengdu 610041, PR China
  • ,
  • Yu Li

      Affiliations

    • Department of Orthodontics, West China College of Stomatology, Sichuan University, Chengdu 610041, PR China

Received 28 April 2007; accepted 1 October 2007. published online 10 December 2007.

Abstract 

Background

The studies on biomechanics of orthodontic tooth movement (OTM) are mainly performed at analytical, tissue and cellular levels. The prime aim of this study was to elucidate the periodontal response to orthodontic force loading by integrating biomechanical and biological approaches.

Methods

We designed and conducted a multilevel study consisting of three parts. (1) At the analytical/theoretical level, 3D finite element (FE) method was used to analyze stress distribution and changing during OTM. (2) At the tissue level, we explored the effects of tensile and compressive forces on the expressions of Type I collagen, matrix metalloproteinases Type I (MMP-1) and tissue inhibitor of metalloproteinase Type I (TIMP-1) in rat’s periodontal ligament (PDL) in vivo. (3) At the cellular level, we studied the effects of variant strain patterns and magnitudes on functional expression of rat’s osteoblasts in vitro.

Findings

(1) In the 3D FE model, the canine tipping and bodily movements showed different ways in stress distribution and degeneration. However, in both tooth movement modalities, tensile zones and compressive zones had similar stress distribution pattern. (2) Tensile and compressive forces imposed different effects on the expressions of Type I collagen, MMP-1 and TIMP-1 in PDL, with Type I collagen and TIMP-1being increased significantly in the tensile zones and MMP-1 being increased significantly in both zones. (3) Differences in strain pattern (dynamic vs. static) and magnitude (light vs. heavy) resulted in different levels of osteoblast’s functional expression indicated by alkaline phosphatase (ALP) and osteocalcin (OC). It was found that dynamic loading was more effective for ALP expression whilst static loading was more effective for OC secretion and 3kPa strain force in vitro was optimal for the both.

Interpretation

It is suggested that there may exist an optimal force system in both magnitude and pattern of loading that could induce efficient OTM.

Keywords: Biomechanics, Tooth movement, Finite element method, Stress, Periodontal cell, Orthodontics

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0268-0033(07)00246-X

doi:10.1016/j.clinbiomech.2007.10.016

Clinical Biomechanics
Volume 23, Supplement 1 , Pages S59-S66, 2008