Clinical Biomechanics
Volume 22, Issue 1 , Pages 100-105, January 2007

A comparison of conventional versus locking plates in intraarticular calcaneus fractures: A biomechanical study in human cadavers

  • Karl Stoffel

      Affiliations

    • Fremantle Orthopaedic Unit, University of Western Australia, Alma Street, B. Block, Level 6, Fremantle, Western Australia 6160, Australia
    • Corresponding Author InformationCorresponding author.
  • ,
  • Grant Booth

      Affiliations

    • Fremantle Orthopaedic Unit, University of Western Australia, Alma Street, B. Block, Level 6, Fremantle, Western Australia 6160, Australia
  • ,
  • Stephan M. Rohrl

      Affiliations

    • Fremantle Orthopaedic Unit, University of Western Australia, Alma Street, B. Block, Level 6, Fremantle, Western Australia 6160, Australia
  • ,
  • Markus Kuster

      Affiliations

    • Fremantle Orthopaedic Unit, University of Western Australia, Alma Street, B. Block, Level 6, Fremantle, Western Australia 6160, Australia
    • Orthopaedic Department, Kantonsspital St.Gallen, St.Gallen 9007, Switzerland

Received 6 January 2006; accepted 28 July 2006. published online 28 September 2006.

Abstract 

Background

Internal fixation of displaced intraarticular calcaneal fractures in patients older than 50 years remains controversial. This is, in many cases, due to fear of loss of fixation and the risk of implant failure in osteoporotic bone. It is the objective of this study to compare the fixation strength obtained using calcaneal plates with and without locking screws, in the fixation of osteoporotic cadaveric intraarticular calcaneal fractures.

Methods

In seven pairs of fresh frozen lower limbs cadavers, intraarticular calcaneal fractures were created with a dynamic single impact loading device and stabilized using either the low profile locking plate, or the conventional calcaneus plate. Radiographs were obtained to assess reduction. The specimens were then subjected to cyclic loading followed by loading to failure, using matched pairs of cadaveric lower limbs. The Wilcoxon signed rank test was used to test for differences in the results.

Findings

The locking plate showed a significant lower irreversible deformation during cyclic loading and a significant higher load to failure. The difference between the ultimate displacement, and work to failure was not significant. A low bone mineral content in the area of the posterior facet correlated only in the conventional plate group with increased irreversible deformation.

Interpretation

This study supports the mechanical viability of using locking calcaneal plates for the fixation of intraarticular calcaneal fractures in elderly patients.

Keywords: Calcaneal fracture, Plate fixation, Locked screws, Conventional screws, Biomechanical testing

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0268-0033(06)00156-2

doi:10.1016/j.clinbiomech.2006.07.008

Clinical Biomechanics