Mechanical properties of callus in human tibial fractures: a preliminary investigation

  • C.Ian Moorcroft

      Affiliations

    • School of Engineering and Advanced Technology, Staffordshire University, P.O. Box 333, Beaconside, Staffordshire ST18 0DF, UK
    • Corresponding Author InformationCorresponding author
  • ,
  • Peter J Ogrodnik

      Affiliations

    • School of Engineering and Advanced Technology, Staffordshire University, P.O. Box 333, Beaconside, Staffordshire ST18 0DF, UK
  • ,
  • Peter B.M Thomas

      Affiliations

    • Department of Orthopaedic Surgery, School of Postgraduate Medicine, Thornburrow Drive, Hartshill, Stoke-on-Trent, UK
  • ,
  • Roger H Wade

      Affiliations

    • Department of Orthopaedics, North Staffordshire Royal Infirmary, Hartshill, Stoke-on-Trent, UK

Received 23 April 2001; accepted 21 August 2001.

Abstract 

Objective. Investigate the mechanical properties of callus in tibial fractures treated with external fixation. In particular any time-dependent or non-linear characteristics.

Design. A clinical-based investigative study.

Background. A fracture bending stiffness in the sagittal plane of 15 N m/deg. has been stated as a satisfactory endpoint of clinical healing. However using this criterion in 76 previous tibial fractures, four continued to a malunion.

Methods. Fracture properties were measured in clinic. The fixator was removed for the tests and a specially designed system was used to measure displacement and load. Fracture stiffness was measured in different planes and at various loading rates. Passive stressing of the leg was performed whilst fracture displacement was recorded. A constant load was applied for a longer period to assess creep properties.

Results. Fracture stiffness was found to vary between different planes of measurement and on load rate. The visco-elastic characteristics of the callus changed with time. In early measurements, the callus absorbed a large proportion of energy when a load was applied. Later tests showed a progressive change with the callus absorbing less energy. This demonstrates that the properties of the callus changed with time, with the viscous element diminishing and the elastic element increasing. This sometimes occurred with no change in the measured fracture stiffness.

Conclusions. Further investigation is needed, focusing on the visco-elastic properties of callus, to develop a more reliable method of determining clinical union.

Relevance

Improved understanding of the mechanical properties of callus could result in improved methods of measuring fracture healing.

Keywords:  Fracture stiffness, Visco-elastic, Fracture healing, External fixation

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0268-0033(01)00079-1

Clinical Biomechanics
Volume 16, Issue 9 , Pages 776-782, November 2001