Clinical Biomechanics
Volume 16, Issue 8 , Pages 710-713, October 2001

Effect of errors in the identification of anatomical landmarks on the accuracy of Q angle values

School of Health Care Professions, University of Salford, Brian Blatchford Building, Salford, Manchester M6 6PU, UK

Received 22 November 2000; accepted 11 May 2001.

Abstract 

Objective. To determine the effect of error in the location of the anterior superior illiac spine, and the centres of the patella and tibial tuberosity, on the measured value of the quadriceps angle.

Background. The quadriceps angle is said to be relevant in the etiology and management of patello-femoral pain. However, the issues around measurement accuracy have not been reported.

Methods. Errors between 1 and 5 mm were introduced to the medial/lateral and vertical co-ordinate data describing the position of the anterior superior illiac spine, the centre of the patella and the centre of the tibial tuberosity, and the effect on the quadriceps angle determined.

Results. Errors between 1 and 5 mm in the medial/lateral location of the centre of the patella produced changes in the quadriceps angle between 1.13° and 5.53°. Errors between 1 and 5 mm in the medial/lateral location of the tibial tuberosity produced changes in the quadriceps angle between 1.02° and 5.18°.

Conclusions. The quadriceps angle is highly sensitive to error in the definition of the centre of the patella and tibial tuberosity. As an approximation, these centres need to be defined with an accuracy of less than 2 mm if the error in the quadriceps angle is to remain below 5°.

Relevance

Until a clinical technique for measuring the quadriceps angle with a high level of accuracy is developed, the clinical use of the quadriceps angle is questionable.

Keywords:  Quadriceps angle, Accuracy, Marker placement error, Patello-femoral pain

To access this article, please choose from the options below

Login to an existing account or Register a new account.

  • Purchase this article for 31.50 USD (You must login/register to purchase this article)

    Online access for 24 hours. The PDF version can be downloaded as your permanent record.

  • Subscribe to this title

    Get unlimited online access to this article and all other articles in this title 24/7 for one year.

  • Claim access now

    For current subscribers with Society Membership or Account Number.

  • Visit SciVerse ScienceDirect to see if you have access via your institution.
 

PII: S0268-0033(01)00045-6

Clinical Biomechanics
Volume 16, Issue 8 , Pages 710-713, October 2001